Portal de Lorca

www.portaldelorca.com

Lorca - SpanishLorca - English
detail of Lorca

 

Lorca City Council improves safety of schoolchildren in 15 schools over the county, with the replacement of electrical (20/08/2010)

Councilman lorquino Consistory Education explained that the renewal of dashboards and protection, power lines and reading devices are some of the actions carried out this summer that also allow for greater energy efficiency.

The Councillor for Education of the City of Lorca, José Joaquín Peñarrubia, has reported that the "Lorca Consistory has worked this summer on improving the safety of electrical installations in 15 schools in the municipality, which were obsolete, with what is to avoid risks among school children. "

Peñarrubia stressed that "the upgrading and replacement of these pipes and the replacement of existing electrical panels to conform to the rules, have been a chapter that has received a battery of specific actions from the beginning of this legislature, and especially this summer, requiring the necessary completion of reforms and optimizing the wiring for the control, student safety and energy efficiency. "

Schools that have benefited from these improvements are the Virgen de las Huertas, The Wire, La Campana, José Robles, San Fernando, Andrés García Soler, La Torrecilla, Pérez de Hita, Petra Gonzalez, Villaespesa, Juan Gonzalez, Virgin Rosario, San Miguel de Zarzadilla of Totana, Juan Navarro de la Hoya and Narciso Yepes de Marchena.

This battery of improvements in power lines has been an investment estimated at 180,000 euros.

This investment program is part of an ambitious plan for improving municipal education infrastructure of the municipality and within the City program to reduce energy consumption and therefore CO2 emissions to the atmosphere.

Specifically, they have replaced the existing electrical panels, adapted to current regulations, which will be necessary to carry out reforms in the electric system.

In particular, each college has taken the following actions:

Public School Virgen de Las Huertas:

Replacing the Command and General Schedule Protection.

(CGMP)

Replacement Side Tables Plant.

Replacing power lines between General Schedule Control and Protection and Side Tables.

The Public School Listen:

CGP and Equipment Replacement Power Reading.

The Bell Public School:

CGP and Equipment Replacement Power Reading.

José Robles Public School:

Replacing the Command and General Schedule Protection.

San Fernando Bar Association:

Replacing the Command and General Schedule Protection.

Replacing existing Schuko Socket outlets at school by new ones with child protection.

Andrés García Soler CP

Placing a protective door to cover the electrical box of infant classrooms.

Replacing the cabinet recessed exístete in elementary classrooms.

Placing emergency lighting on the tables reformed.

Torrecilla CP

Transfer of the accountant general of the center to front line.

The installation of a new individual derivation.

Replacement of existing general cabinet.

Transfer of existing general cabinet.

Relocation and replacement of cabinet of a room for children.

Emergency lighting on the tables reformed.

CP Perez de Hita

Running a new line deliverer from the overall picture to classrooms 2.

He moved the center picture complemented with new chassis for circuit breakers.

He also renewed wiring.

In the overall picture, it is planned to install a set of miniature circuit breakers, comprising a type MCB 4P 16A, another type 4P, 125A, 100A 4P, 4P 2P 50 th and 16 A.

It will replace the electrical control and protection located on the 1st floor of the classroom building 3 new one.

The cabinet on the ground floor of Lecture 2, is replaced by another, whose capacity is 30% higher.

Placement of a circuit for various uses designed to serve the copy room of classrooms 2.

Cleavage line plugs child classes downstairs.

Emergency lighting on the tables reformed.

CP Petra Gonzalez

The performance in this school includes actions aimed at adapting the system total power distribution to the current rules, based on new or box counters that some individual referral to a new general framework that brings together the distribution to all buildings , a new underground network of distribution and reform undertaken and adjustments to all buildings and switchboards.

Replacing the existing electrical box in the locker room for new gold.

In the classrooms of children is projected to replace the recessed electrical box with a new surface, with a capacity increase of 30%.

The making of a new connection to each one of the buildings.

Emergency lighting on the tables reformed.

College Villaespesa

Relocation and replacement of the picture control, protection and distribution which is currently abroad on a new cabinet which will consist of protective elements and thermal magnetic circuit breaker 160A

Colegio Juan González

Transfer of the accountant general of the center outside the building, according to Company policies supplier.

It made the diversion of low-voltage power line to which the changes will be necessary for the movement of the connection exists.

Also replaced the overall picture of control, protection and distribution center with a new one will consist of a cabinet with thermal magnetic switch 160A, generally muddy and overload and adequate to protect existing services on the premises.

Will proceed to bury the lines feeding the classrooms of children through the schoolyard.

These lines will leave the panel for the center and end in the corresponding table of distribution and delivery.

Finally, install the said new distribution switchboard and providing service to the classrooms of children, such schedule shall consist of cabinet insulation and protection for existing services and general MCB is 4-pole 100A each and three Output protection circuit breakers 4 poles 40A each.

Colegio Virgen del Rosario

Transfer of electric energy meter outside the building center.

Finally and to reach the current point to the center line in the opening shall slash in the perimeter wall of the enclosure to get to grips with the current onslaught from underground installation rate across to the building for which opens a new line of low voltage underground regulatory trench under concrete pipe, with opening and closing the trench.

.

Colegio San Miguel

Outdoor installation of a new panel for the center to divide the various modules.

To carry out a cabinet install polyester insulation for external mounting with mounting plate, general MCB 80 A 4-pole breakers and three outputs for protection of 2-pole 40 A each.

Juan Navarro College

Transfer of the accountant general of the center to clear the space for a new door to the enclosure to which the new facility is required by standards of the firm.

Module supplier of polyester insulation for electrical energy meter with indirect measurement equipment, with brick and mortar coating for protection.

It made the diversion of low-voltage power line.

Installing a new picture deal the referrals to the various modules that make up the center.

Narciso Yepes school

Review of the lighting in different classrooms and toilets by mounting, connection and commissioning of fluorescent screens, type of 2x26 W, with electronic ballast in the classroom and 1x36 W, with electronic ballast and watertight model toilets .

Source: Ayuntamiento de Lorca

Notice
UNE-EN ISO 9001:2000 - ER-0131/2006 Región de Murcia
© 2024 Alamo Networks S.L. - C/Alamo 8, 30850 Totana (Murcia) Privacy policy - Legal notice - Cookies
Este sitio web utiliza cookies para facilitar y mejorar la navegación. Si continúas navegando, consideramos que aceptas su uso. Más información